Standard specifications Motor safety switchers Serie MSM 600/25

  • Standard specifications

    Standard specifications Motor safety switchers Serie MSM 600/25
    Switch insert
    Rated operating voltage Ue 690 V
    Rated insulation voltage Ui 690 V
    Rated impulse withstand voltage, Uimp 6 KV
    Pollution level 3
    Utilization category AC3
    Rated frequency 50/60 Hz
    Rated operating mode Continuous operation
    Rated operating current Ie See Model list
    Thermal overload trip See Model list
    Temperature compensation (reference values to VDE / IEC) -5°C … +55°C
    Trip class 10 A
    Mechanical life time 0,1 x 106 operating cycles
    Temperature compensation operating range -20°C … +55°C
    Storage temperature -10°C … +40°C
    Protection class IP2LX
    Mounting position preferably vertical
    Actuating current of short-circuit trip In line with the setting range fixed at 12 x Ie +/- 20%
    Auxiliary contacts  
    Rated continuous current Iu 6 A
    Rated insulation voltageUi 500 V
    Rated operational current Ie 500 V
    Utilization category AC 15 für Ie = 2A
    Electronic-compatible 24 V - 10 mA
    Undervoltage trip  
    Rated actuating voltage Ue 24 V, 110 V, 230 V, 400 V each with 50 Hz Other voltages on demand
    Responding value 0,7 … 0,35 Ue
    Shunt trip  
    Rated actuating voltage Ue 24 V, 110 V, 230 V, 400 V each with 50 Hz Other voltages on demand
    Responding value 0,7 … 1,1 Ue
  • Model

    Model
    Type Rated current Setting range of thermal release
    35/016 0,16 A 0,10 A ... 0,16 A
    35/000 0,25 A 0,16 A ... 0,25 A
    35/001 0,40 A 0,25 A ... 0,40 A
    35/002 0,63 A 0,40 A ... 0,63 A
    35/003 1,00 A 0,63 A ... 1,00 A
    35/004 1,60 A 1,00 A ... 1,60 A
    35/005 2,50 A 1,60 A ... 2,50 A
    35/006 4,00 A 2,50 A ... 4,00 A
    35/007 6,30 A 4,00 A ... 6,30 A
    35/008 10,00 A 6,30 A ... 10,00 A
    35/009 16,00 A 10,00 A ... 16,00 A
    35/010 20,00 A 16,00 A ... 20,00 A
    35/011 25,00 A 20,00 A ... 25,00 A
  • Accessory

    Accessory
    Type Article  
    39/00 Auxiliary contacts 1Ö / 1S
    39/01 Auxiliary contacts 2S
    39/03 Auxiliary contacts
    39/02 Auxiliary contacts , advanced 1Ö / 1S
    39/021 Auxiliary contacts , advanced 2S
    39/10 Undervoltage trip 110 V, 50 Hz
    39/11 Undervoltage trip 230 V, 50 Hz
    39/12 Undervoltage trip 400 V, 50 Hz
    39/20 Shunt trip 110 V, 50 Hz
    39/21 Shunt trip 230 V, 50 Hz
    39/22 Shunt trip 400 V, 50 Hz
    39/49 PEN-terminal  
    39/701 Indicator light white 220 V
    39/711 Indicator light green 220 V
    39/721 Indicator light red 220 V
    39/702 Indicator light white 400 V
    39/712 Indicator light green 400 V
    39/722 Indicator light red 400 V
    39/40 Front panel IP41
    39/41 Front panel IP55
    39/80 STOP-button  
    39/81 Emergency Stop, catching  
    39/88 Sealer  
    39/50 Insulated enclosure IP41
    39/51 Insulated enclosure IP55
    40/55 Insulated enclosure with CEE-plug 5-pin
    40/56 Insulated enclosure with CEE-plug 5-pin with turner

Downloads